Intrinsically Safe Gas-Sentry detectors for combustible gas and oxygen with optional sensors for carbon monoxide, and hydrogen sulfide are used for residential CO inspections and testing the safety of ambient air during post fire overhaul and confined space entry, and locating leaking gas or accelerants.

Locating Leaking Combustible Gas
Bright LED Numeric & Alpha Display
High precision numeric display with flashing alpha descriptors indicating which scales are alarming
Full Range of Gas on %GAS and %LEL Scales
Catalytic combustion and thermal conductivity sensors detect the full range of combustible gas
TRACK GAS Scale
High precision with quick response for locating leaking combustible gas
Automatic Calibration
Catalytic combustion, oxygen and CO / H2S sensor automatically calibrate in 30 seconds
Optional Calibration Verification
Docking stations automatically supply calibration gases and record calibration data
CO / H2S Sensor
Toxic gas (CO / H2S) sensor which is CO specific when used with in-line interference filter
|
Model No.
|
Combustible
% Gas
|
Gas
%LEL
|
Carbon Monoxide
CO
|
Oxygen
O2
|
Other Specifications
Applicable to All
|
|
CGO-321
|
0-100%
|
0-100%
|
*****
|
0-40%
|
* Warm-up: 10 sec.
|
|
CGA-401
|
*****
|
0-100%
|
0-5000 ppm
|
0-40%
|
* Pwr. Supply: 4AAs
|
|
CO-150
|
*****
|
*********
|
0-5000 ppm
|
*****
|
* Op. Temp.: -30/50C
|
|
***********
|
*****
|
*********
|
*****
|
*****
|
* Weight: 20 ounces
|
|
***********
|
*****
|
*********
|
*****
|
*****
|
* Pump: Std.Internal
|
|
***********
|
*****
|
*********
|
*****
|
*****
|
* Auto. Cal.:30 sec.
|
|
***********
|
*****
|
*********
|
*****
|
*****
|
* Alarms: Vis.& Aud.
|
Note: the CGO-321 calibrates on methane and the CGA-401 cals. on pentane.

Autozeroing Gas-Sentry on Clean Air